HyperVAP HV300 Gas Purging Evaporation Concentrator - Sample Capacity
: Number of Samples: 6~32 Sample Volume (mL): 1~300 - Pressure : Operation Gas Pressure (psi): 15~50 - Dimension(W x D x H): 590 x 340 x 320 mm - Weight: 26.5 kg |
Product Features
• Accelerated evaporation performance by gas purging mechanism
• Automated, programmable and reproducible
• Proprietary semi-helical gas flow mechanism to achieve the highest evaporation rate
• Diverse dimensions of nozzles and tube racks can be tailored upon customer needs.
• Four independent timer settings for different solvents
• Dual-step control of gas pressure and time to prevent “bumping” of the sample on startup
• Differentiated monitoring functions: 3-side transparent glass panels, blue backlight (on/off switchable) and traffic lights
• Optimized for evaporating organic solvents including sample preparations for chromatography
Safety features: tempered glass panels, automatic gas shutoff function, traffic lights (fan, door, heater)
• Automated, programmable and reproducible
• Proprietary semi-helical gas flow mechanism to achieve the highest evaporation rate
• Diverse dimensions of nozzles and tube racks can be tailored upon customer needs.
• Four independent timer settings for different solvents
• Dual-step control of gas pressure and time to prevent “bumping” of the sample on startup
• Differentiated monitoring functions: 3-side transparent glass panels, blue backlight (on/off switchable) and traffic lights
• Optimized for evaporating organic solvents including sample preparations for chromatography
Safety features: tempered glass panels, automatic gas shutoff function, traffic lights (fan, door, heater)
Applications
• Pharmaceutical biotech compounds
• Clinical samples
• Environmental samples
• Forensic and crime samples
• Agrochemical samples
• Food and beverage analysis
• Clinical samples
• Environmental samples
• Forensic and crime samples
• Agrochemical samples
• Food and beverage analysis
Maximized Evaporation by Semi-helical Air Flow (Patented)
Reference Data
Pressure /Solvent |
40 psi |
30 psi |
20 psi |
Hexane |
1:50 |
2:10 |
3:20 |
Methanol |
5:10 |
6:30 |
9:50 |
Acetonitrile |
5:45 |
7:10 |
11:40 |
Ethanol |
6:10 |
8:30 |
15:30 |
Experimental Conditions
- Sample volume : 5 mL in 20 mL tube
- Temperature : 40℃
- Gas : nitrogen gas
- Sample volume : 5 mL in 20 mL tube
- Temperature : 40℃
- Gas : nitrogen gas
Model |
HyperVAP |
Sample capacity |
Number of samples: 6~32 / Sample volume (mL): 1~300 |
Gas |
Compressed air, N2, etc. |
Pressure |
Operation gas pressure (psi): 15~50 Pressure control: Automated dual-step control (initial & operating pressure) |
Max. time for initial pressure (min) |
~ 99 |
Max. time control (min) |
~ 999 (4 independent channels) |
Water bath temperature (℃) |
~ 99 |
Forced vapor evacuation |
Yes (by fan) |
Power requirement (VA) |
800 |
Dimension |
590(W) x 340(D) x 320(H),mm |
Weight (kg) |
26.5 |
HyperVAP Catalog

hypervap_catalog2019.pdf |